The case report by Carrel and colleagues [1] should help surgeons approaching pseudoaneurysms of the coronary button anastomoses after composite graft replacement of the aortic root.

We find that such coronary button false aneurysms are uncommon. We have encountered one such false aneurysm among over 500 composite graft root replacements performed (Figure 1). This was in a patient later found to harbor a pathogenic mutation in the TGFBR2 gene (causative of Loeys-Dietz syndrome), which might have contributed to additional tissue weakness. We have repaired several such aneurysms referred from other centers. We believe that careful tightening of the coronary button suture line is of critical importance in avoiding such problems.

Figure 1.

Computed tomography scan demonstrating a large 12.5 cm pseudoaneurysm originating from the right coronary button in a patient after composite graft aortic root replacement.

media/vol4/issue6/images/aorta-04-248-g001.jpg

In our experience, these anastomotic pseudoaneurysms are seen more commonly at the right coronary artery button. These present a special problem, as there is often an accompanying large pseudoaneurysm located anteriorly under the breastbone and in front of the aorta.

Like Carrel and colleagues [1], we also expose the femoral artery and vein for safety prior to redo sternotomy. Once safely through the bone, we dissect just enough to permit spreading the retractor (Figure 2). We leave the pseudoaneurysm intact. We cannulate femorally and assume cardiopulmonary bypass. If we have been able to surround the upper aorta (scenario 1), we do not need deep hypothermic circulatory arrest (DHCA). We simply clamp the aorta and move on. If surrounding the upper aorta is not feasible (scenario 2), we go on to deep hypothermic circulatory arrest (we employ a low threshold for DHCA to avoid difficult to control hemorrhage). Either with the aorta clamped (scenario 1) or on DHCA (scenario 2), we open the false aneurysm (Figure 3). Once the clot is scooped away, the RCA button anastomosis is usually easily exposed and well-visible (Figure 4). Like Carrel and colleagues [1], we find that tightening the anastomosis and placing one or two stitches suffices. In this case (RCA pseudoaneurysm) the sutures are all placed from outside the aortic graft, without ever opening it. We then rewarm and wean from cardiopulmonary bypass.

Figure 2.

Appearance of the pseudoaneurysm upon re-entry into the chest.

media/vol4/issue6/images/aorta-04-248-g002.jpg
Figure 3.

The pseudoaneurysm is opened and the right coronary button with a leaking suture is identified.

media/vol4/issue6/images/aorta-04-248-g003.jpg
Figure 4.

Schematic illustration showing how a loose suture of the right coronary artery button can cause a leak, which ultimately leads to pseudoaneurysm formation.

media/vol4/issue6/images/aorta-04-248-g004.jpg

The two anatomic lesions, LCA and RCA pseudoaneurysm, present different anatomic challenges. In LCA pseudoaneurysm, the accompanying clot-filled false aneurysm is posteriorly located and is not even exposed surgically. In RCA pseudoaneurysm, the clot-filled false aneurysm covers the aortic region and impairs aortic and cardiac access. The surgeon not only “sees” the clot-filled false aneurysm, but traverses it to accomplish the repair.

Performing RCA pseudoaneurysm repair through the pseudoaneurysm simplifies the procedure immensely, obviating tedious and dangerous dissection to access and dissect cardiac structures directly.

Conflict of Interest

The authors have no conflict of interest relevant to this publication.

References

  1.  
    Carrel T, Hurni S, Huber C, Englberger L. Simplified Approach to Repair Early Pseudoaneurysm of the Left Coronary Button Following Composite Graft Because of Acute Type A Aortic Dissection. Aorta (Stamford). 2016;4:210-213. DOI: 10.12945/j.aorta.2016.16.031

PDF

Download the article PDF (592.65 KB)

Download the full issue PDF (13.84 MB)

Mobile-ready Flipbook

View the full issue as a flipbook (Desktop and Mobile-ready)

Cite this article as: Elefteriades JA, Kopf GS, Ziganshin BA. Minimalist’ Trans-Aneurysmal Approach to Coronary Button Pseudoaneurysm. AORTA (Stamford). 2016;4(6):248-250. DOI: 10.12945/j.aorta.2016.16.082

You must be registered and logged in to leave comments.

There have been no comments posted yet

All comments will be screened and reviewed before posting. Statements, opinions, and results of studies published in AORTA Journal are those of the authors and do not reflect the policy or position of The Journal and Science International and the Editorial Board and provides no warranty as to their accuracy or reliability. Material is copyrighted and owned by Science International and cannot be used without expressed permission.